Power input | Rated voltage | 3-phaseAC220V/AC230V/AC380V/AC400V/AC415V/AC440V/AC460V/AC480V 1-phase AC220V/AC230V | |
Rated input current | See Section 2.3 inuser manual | ||
Frequency | 50Hz/60Hz, acceptablefluctuation range ±5% | ||
Allowable range ofvoltage | Continuous voltagefluctuation ±10%, short fluctuation -15%~+10%, i.e. 323V~528V; Voltage out-of-balancerate <3%, distortion rate as per the requirements of IEC61800-2 | ||
Power output | Standard applicablemotor (kW) | See Section 2.3 inuser manual | |
Rated current (A) | See Section 2.3 inuser manual | ||
Output voltage (V) | 3-phase: 0~ ratedinput voltage, Bias < ±3% | ||
Output frequency (Hz) | 0.00~ 600.00Hz; unit:0.01Hz | ||
Overload capacity | 150% - 1min; 180% -10s; 200% - 0.5s once per 10 minutes | ||
Operationcharacteristics | Control mode | V/f control Sensor-less vectorcontrol without PG 1 Sensor-less vectorcontrol without PG 2 | |
Range of speedregulation | 1:100 ( V/f control,sensor-less vector control without PG 1) 1:200 (sensor-lessvector control without PG 2) | ||
Speed accuracy | ±0.5% (V/f control) ±0.2% (sensor-lessvector control without PG 1 & 2) | ||
Speed fluctuation | ±0.3% (sensor-lessvector control without PG 1 & 2) | ||
Torque response | < 10ms (sensor-lessvector control without PG 1 & 2) | ||
Starting torque | 0.5Hz: 180% (V/fcontrol, sensor-less vector control without PG 1) 0.25Hz: 180%(sensor-less vector control without PG 2) | ||
Basic functions | Start frequency | 0.00~ 600.00Hz | |
Acceleration/decelerationtime | 0.00~60000s | ||
Carrier frequency | 0.7kHz~16kHz | ||
Frequency commandsource | Digital command +operating panel ∧/∨ Digital command +terminal UP/DOWN Communication Analog command(AI1/AI2/EAI) Terminal pulse command | ||
Motor Started method | Started from startingfrequency DC braking and thenstarted Speed search thenstarted smoothly | ||
Motor Stopped method | Ramp to stop Coast to stop Ramp stop + DC brake | ||
Basic functions | Dynamic brake capacity | Brake unit actionvoltage: 650V~750V; service time: 0.0~100.0s; brake unit for GK600-4T45G/55Lor below could be internally mounted | |
DC brake capacity | DC brake startfrequency: 0.00~600.00Hz DC brake current:0.0~100.0% DC brake time:0.0~30.00s | ||
Input terminals | Six digital inputterminals (can be extended to 7), one of which can be used for high-speedpulse input. Compatible with active open collectors NPN, PNP and dry contact input Two analog inputterminals, one of which is voltage/current programmable, and the other isvoltage only (can be extended to 3; extension terminal is voltage/currentprogrammable) | ||
Output terminal | One high-speed pulseoutput terminal, 0~50kHz square wave signal output; can output signals suchas setting frequency and output frequency. etc One digital outputterminal One relay outputterminal (can be extended to 2) | ||
One analog outputterminal (can be extended to 2), voltage/current output optional; can outputsignals such as setting frequency and output frequency, etc | |||
Characteristics | Parameter copy,parameter backup, common DC bus, free switching between two motors'parameters, flexible function code displayed & hidden, various main &auxiliary command and switchover, speed searching, a variety ofacceleration/deceleration curves optional, automatic correction of analogvalue, mechanical brake control, 16-step speed control programmable (2-stepspeed supports flexible frequency command), swing frequency controlprogrammable, fixed-length control, counting function, three faults recorded,over excitation braking, over voltage stall prevention, under voltage stallprevention, restart upon power off, hopping frequency, frequency binding,free switching between four sections of acceleration/deceleration time, motorthermal protection, flexible fan control, process PID control, simple PLC,flexible multi-functional key setting, droop control, parameteridentification, weak magnetic control, high-precision torque restraint, V/fseparated control | ||
Protection function | Refer to Chapter VII -Fault Diagnosis and Abnormity Handling | ||
Environment | Place of operation | Indoors, no directsunlight, free from dust, corrosive gases, flammable gases, oil mist, watervapor, water drip or salt content etc. | |
Altitude | 0~2000m Derating is requiredwhere altitude is more than 1,000m; each increase of 100m in heightcorresponds to a decrease in rated output current by 1% | ||
Ambient temperature | -10°C~50°C | ||
Humidity | 5~95%, condensationnot allowed | ||
Vibration | Less than 5.9m/s2(0.6g) | ||
Storage temperature | -40°C~+70°C | ||
Others | Efficiency | Rated power 7.5kW and below: ≥93% 11~ 45kW: ≥95% 55kW and higher: ≥98% | |
Installation mode | Wall-mounted | ||
Protection level | IP20 | ||
Coolingmode | Forced air cooling | ||